F-1576 (Issue 4) 1 of 2
Quiet DieselE Series Operation, Maintenance and Parts
PRE-START CHECKS
Before the first start of the day and after every eight
hours of operation:
1. Check for proper oil and coolant levels.
2. Check for fuel, coolant and water leaks, mechanical
damage, loose parts, damaged exhaust hose, loose
or corroded battery connections, clogged sea water
strainer, and CO monitors that don’t work. Service
as necessary.
3. Check for swimmers that might be exposed to the
engine exhaust.
4. Turn off air conditioners and other large appliances.
PRIMING THE FUEL SYSTEM
If the generator ran out of fuel, push the control switch
to STOP (Prime) and hold for at least 30 seconds.
STARTING THE GENERATOR
1. Push and hold the control switch at START (Pre-
heat) until the generator starts. The amber status
lamp on the control switch will blink rapidly.* The
amber lamp will go out and the green run lamp on
the switch will light after the starter has discon-
nected and the engine is up to speed. (Depending
on how cold the engine is, preheat can take as long
as 15 seconds before cranking starts.)
2. For longer engine life, let the engine warm up for two
minutes before turning on air conditioners and other
large appliances.
3. Check for water, coolant, fuel and exhaust leaks.
Stop the generator immediately if there is a leak.
WARNING
!
Fuel and exhaust leaks can lead to
severe personal injury or death. Shut down the
generator immediately. Repair fuel leaks imme-
diately. Do not run the generator until fuel and
exhaust leaks have been repaired.
4. If the generator fails to start, cranking will discon-
tinue in 20 to 60 seconds, depending on how cold
the engine is, and the amber status lamp will blink
Shutdown Code No. 4. See Troubleshooting (Oper-
ator’s Manual) if the generator does not start after
two or three tries.
CAUTION
!
Do not continue cranking and risk
burning out the starter or flooding the engine
(exhaust flow during cranking is too low to expel
water from the exhaust system). Find out why
the generator does not start and repair as nec-
essary.
5. If the generator shuts down, the amber status
lamp will blink a shutdown code. See SHUTDOWN
CODES below.
STOPPING THE GENERATOR
Turn off air conditioners and other large appliances and
let the generator run for two minutes to cool down.
Then touch the Control Switch to STOP (Prime).
SHUTDOWN CODES
The amber status lamp will blink if the generator shuts
down. It will blink 1, 2, 3, 4, 5 or 7 times, pause, and then
repeat the blinking. The number of blinks is the shut-
down code. Blinking continues for five minutes and
stops. To restore blinking press the control switch to
STOP (Prime) until the amber lamp comes on (3 to 4
seconds). Then press STOP (Prime) three times to re-
stores blinking.
One blink indicates shutdown due to high engine
temperature.
Two blinks indicate shutdown due to low oil pres-
sure.
Three blinks indicate shutdown that may require
service. See Troubleshooting in the Operator’s
Manual.
Four blinks indicate shutdown due to a failure to
start within the time allowed for cranking.
Five blinks indicate shutdown because carbon
monoxide was detected.
Seven blinks indicate shutdown due to a loss of
raw water flow for engine and exhaust cooling.
See Troubleshooting in the Operator’s Manual for
more information.
CUMMINS ONAN DIGITAL DISPLAY
See the generator Operator’s Manual for details.
* The green run lamp and gauges will also flash momentarily.
gpd.sunwayinfo.com.cn
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - F-1576 (Issue 4) 1 of 2

F-1576 (Issue 4) 1 of 2Quiet DieselE Series Operation, Maintenance and PartsPRE-START CHECKSBefore the first start of the day and after every eighthou

Seite 2 - ENGINE FLUID CAPACITIES

Printed in U. S. A. 10/08F-1576 (Issue 4)2 of 2PERIODIC MAINTENANCE SCHEDULEMDKBHMDKBK, MDKBL, MDKBM, MDKBN,MDKBP, MDKBR, MDKBS, MDKBVMDKBT, MDKBUMDD

Kommentare zu diesen Handbüchern

Keine Kommentare