Seitenansicht 24
Standard Repair Times
Procedure Number and Description
Removed
From
Chassis
RABCD
Special
S
In-Chassis
Service Accessibility Codes
9
00901 ADMINISTRATIVE TIME OPEN/CLOSE
REPAIR ORDER (SHOP)
Step 1 Includes: 0.4 −−
Clock on and off the job
Move equipment to and from work area
Record the following:
Generator set model number
Generator set serial number
Engine serial number
Hours of operation
Date in service
Load/unload tools, equipment, and repair parts
Clean up work area
Write repair order
Write repair procedures
08318 FAN REPLACE ALL
Step 1 Includes: −−0.7 −−
Disconnect/reconnect:
Battery
Wire harnesses as necessary
Remove/install:
Fan guards
Fan assembly
Test run unit
10117 AIR CLEANER ASSEMBLY REMOVE AND
INSTALL
Step 1 Includes: −−0.1 −−
Disconnect/reconnect:
Battery
Harnesses as necessary
Remove/install air cleaner assembly
07801 OIL DRAIN/FILL
Step 1 Includes: −−0.2 −−
Drain and fill oil
Seitenansicht 24