SAE J1587* and J1939 Failure Mode Identifiers
(FMI)**
FMI Description
0 Data valid but above normal operational range
1 Data valid but below normal operational range
2 Data erratic, intermittent or incorrect
3 Voltage above normal or shorted high
4 Voltage below normal or shorted low
5 Current below normal or open circuit
6 Current above normal or grounded circuit
7 Mechanical system NOT responding properly
8 Abnormal frequency, pulse width or period
9 Abnormal update rate
10 Abnormal rate of change
11 Failure mode NOT identifiable
12 Bad intelligent device or component
13 Out of calibration
14 Special instructions
15 Data valid but above normal operational range (least severe)
16 Data valid but above normal operational range (moderately
severe)
17 Data valid but below normal operational range (least severe)
18 Data valid but below normal operational range (moderately
severe)
19 Received network data in error
20 Reserved for future assignment
21 Reserved for future assignment
22 Reserved for future assignment
23 Reserved for future assignment
24 Reserved for future assignment
25 Reserved for future assignment
26 Reserved for future assignment
27 Reserved for future assignment
28 Reserved for future assignment
29 Reserved for future assignment
30 Reserved for future assignment
31 Not available or condition exists
* - J1587 FMI numbers run from only 0 to 15.