Electronic Display Description
The ED-3 Electronic Display is an LCD display with 5 menu keys that can display engine
parameters in a variety of formats. Display formats are: basic, analog gauge, graphical, text,
and quad display. The Electronic Display receives engine data from an industry standard
SAE J1708/J1587 or J1939 datalink. Displayable engine parameters will vary with the
engine application, but typically include engine speed, throttle position, system voltage, and
engine load.
Boat speed can also be displayed for some engine applications if a Global Positioning
System (GPS) or a speed transducer is connected on the RS422 receive (RX) input. See the
appendix for connector pinout information.
4
DATALINK Menu
ENGINE Selects the engine model that is connected to the display. Choices
include QSB, QSC, QSM11, QSX, QSK, QST30, 480C-E, M11ECMC,
N14ECMC, and CENTRY. Use the ADJUST key (key 4) to enter the
Setting Menu then use up/down scroll keys (keys 1 and 2) to move
the pointer to the desired engine model. Press the SELECT
key (key 4) to fill in the box in the right hand column adjacent to
the desired model, then press the BACK key (key 5) to return to the
Datalink Menu.
DATA TYPE Selects Data type (J1939 or J1587). Use the ADJUST key (key 4) to
desired setting.
DATA LINK INFO J1587 INFO Allows user to view J1587 message data
(when Data Type is J1587) J1587 VIEWER Allows user to view J1587 raw messages received
by the Display.
NMEA VIEWER Allows user to view NMEA raw messages received by
the Display.
Use the ADJUST key (key 4) to enter the Data Link Info screen. Use
the up/down scroll keys (keys 1 and 2) to move the pointer to the
desired selection followed by the ADJUST key (key 4) to enter the
screen and view the data.
Use the BACK key (key 5) to return to the Data Link Info menu.
J1939 SETTINGS Allows user to configure engine source to suit the configuration of
(when Data Type is J1939)
the installation. Choices include 1 (Actual SA 00), 2 (Actual SA 01),
3 (Actual SA 242), 4 (Actual SA 243), 5 (Actual SA 244) and 6 (Actual
SA 245). Use the ADJUST key (Key 4) to enter the J1939 Settings
screen. Use the ADJUST key (Key 4) to select the desired setting,
press the BACK key (Key 5) to return to the Data- Link Menu.