Steam clean the reusable gaskets. Dry with compressed
air, and check for cuts or deformations in the silicone
bead.
Replace the gasket if there are any cuts, abrasions, or
deformations in the silicone bead. Check to see if the
nylon carrier is cracked or broken; replace if necessary.
NOTE: The reusable gaskets must not be cleaned with
solvent. Solvent will deteriorate and swell the silicone bead
and destroy the gasket. The gaskets must be cleaned with
soap and water.
Inspection
Inspect each cover for cracks or damage, and replace if
necessary.
On the cover fitted with the crankcase breather tube,
inspect the breather baffle for damage.
Rocker Lever Housing Assembly -
Cleaning and Inspection for Reuse
(03-05)
NOTE: On CELECT™ engines while handling the rocker
lever housings, protect the wiring harness pass through
connectors. Do not subject the pass through connectors to
impact forces and do not rest the housing on the face with
the pass through connectors.
Water Manifold Tube - Removal
Remove the o-ring plug and water tube from the water
manifold with service tool, Part No. 3823819.
Insert the jumper tube removal tool into the retainer clamp
slot. Use a pry bar and pry the jumper tube out of the
water manifold.
Discard the o-rings.
Rocker Lever Housing AssemblyRocker Lever Housing Assembly - Cleaning and Inspection for Reuse (03-05)
N14 Page 3-15